TY - JOUR UR - https://doi.org/10.21009/SPEKTRA.051.06 SN - ISSN : print : 2541-3384 dan online : 2541-3392 VL - 5 TI - The Design of Display Digital Data Interface Clamp-Meter Complemented By Sensor GMR (Giant Magnetoresistance) SP - 53 ID - repounp38940 PB - Spektra: Jurnal Fisika dan Aplikasinya IS - 1 Y1 - 2020/04/01/ N2 - This article discusses the design of a robust data interface system that displays an electric current using the GMR sensor. Robust measurement of electrical current to detect magnetic fields contained in the current-carrying wire. The magnetic field on the cable should be the input signal to the GMR sensor to be processed by the interface program. This interface used the Arduino IDE program and displayed in the LCD screen. This research is an experimental research laboratory. The results of the data interface can be displayed in the form of comparative measurements with the power of the conventional electric current. Comparison measurements can be viewed in graphical form. The results of the study have an average measurement accuracy of 91.2%, with an average of 0.96. Besides, this study also obtained a standard deviation of 0.21 and an average error of 0 : 08. KW - GMR KW - clamp-meter KW - interface KW - Arduino Uno EP - 60 JF - Spektra: Jurnal Fisika dan Aplikasinya A1 - Yulkifli, Yulkifli A1 - Afriani, Fitri A1 - Yohandri, Yohandri A1 - Ramli, Ramli AV - public ER -